Demo · synthetic sample unit · no client data CUI inspection prioritization

Where should the inspection team look first?

Corrosion under insulation hides. Stripping and screening every insulated circuit is not an option, so someone has to decide the order. This workbench takes the circuit list, its operating context and the inspection history a plant already holds, and turns them into a ranked, explainable look-here-first list.

It is a decision-support layer, not a replacement for the inspector's judgment or for API 583 practice. Every score shows what drove it, every weight can be changed, and the backtest below shows how the order would have performed against known findings.

Input

Circuit attributes you already track: material, operating temperature, insulation and jacketing, coating, environment, damage points, dates, prior findings.

Output

A ranked list with priority tiers and the three drivers behind each score, plus a first-look suggestion per circuit.

Pressure test

Hide the findings from one historical campaign, rank the circuits blind, and count how many real findings sit at the top of the list.

Ranked listForty-eight insulated circuits on one sample unit, ordered by CUI likelihood.

Move a weight and the order, the tiers, the backtest and the plan all update together. Click a row for the full record.

How the score is built

Each circuit gets a 0 to 1 reading on eight factors drawn from API RP 583 and the CUI damage-factor logic in API 581. The weights start from published guidance. In a pilot they are recalibrated from your own findings.

Temperature bands used

Carbon steel: susceptible from about −12 °C to 175 °C, worst between roughly 50 °C and 120 °C. Austenitic stainless: chloride stress-corrosion cracking risk from about 50 °C to 175 °C. Cyclic or intermittent service raises the reading. Ranges follow API RP 583 guidance and are adjustable per site.

#CircuitScoreTierWhat drives itLast insp.

BacktestRank blind, then check the order against what the last campaign actually found.

This sample unit has … circuits with CUI in its history. The curve shows how quickly each ordering reaches them.

Share of known CUI findings reached, by share of circuits inspected

Workbench orderTime-since-inspection orderRandom order
Gain chart: findings reached versus circuits inspected

Hover for values. A curve that climbs early means the crew meets the real problems first. Ordering by time since last inspection is the common default when no risk model is in place.

What the inspection team getsA first-look plan for the top of the list, in language a crew can act on.

The workbench decides the order. Your inspection procedures decide the method. The suggestions here are illustrative.

#CircuitWhy it is hereSuggested first look

See the unit in 3DEvery reading point on the rack, and a probe that works the list in order.

A clay model of the same 48 circuits. Click any pipe for its record, run the sweep to watch the findings appear in rank order, pull the insulation layers apart, and print the spec sheet.

Open the reading simulation
Sample unit · 48 circuits · drag to turn
The 3D preview needs WebGL. Open the full simulation instead.
Explore the model
What we need from you

One anonymized export, or one page on how you plan today.

Either is enough to pressure-test the approach. No meetings are required. Questions go by email to a named technical contact and are answered in writing within a day.

Option A · backtest

A historical, anonymized circuit export

One unit or one campaign, 150 circuits or more, with the findings included. We hide the findings, rank blind, and send back a written scorecard like the panel above, using your numbers instead of sample ones.

Option B · workflow

How prioritization happens today

A short description of the current planning cycle (RBI software, spreadsheets, engineer judgment) and a sample planning list. We map where a ranked, explainable list would slot in and what it would change.

ColumnExampleNeeded
circuit_idP-310-014, or a hash you generateRequired
materialCS, SS, low alloyRequired
op_temp_c88, or a band such as 50–120Required
serviceSour waterRequired
cyclic_serviceY / NHelpful
insulation_typeCalcium silicateRequired
jacket_typeAluminumHelpful
jacket_conditionGood / Fair / Poor at the last walkdownRequired
coatingNone / Organic / TSA, with year if knownRequired
insulation_year2004Helpful
last_inspection_date2019-06Required
environment_tagscooling-tower drift; wash-down zoneHelpful
damage_points3 supports; 1 dead leg; 2 penetrationsHelpful
prior_cuiY / NHelpful
criticality1 to 4, or your RBI consequence classHelpful
findingCUI found Y / N, max wall loss %Required for the backtest
circuit_id,material,op_temp_c,service,cyclic_service,insulation_type,jacket_type,jacket_condition,coating,insulation_year,last_inspection_date,environment_tags,damage_points,prior_cui,criticality,finding

Not needed: client or site names, P&IDs or drawings, coordinates, cost data, or any personal information. Circuit IDs can be hashed on your side before export.

How the pilot runs

Four steps, by email, in about three weeks.

Nothing here needs a meeting. If the blind ranking does not beat the order you would have used anyway, the report says so and we stop there.

  1. STEP 1You · about an hourSign the NDA, send the export

    Or the one-page workflow description. Name one technical contact for written questions.

  2. STEP 2Clear Anvil · one weekRank blind, then unblind

    Findings are held back, circuits are ranked from attributes and history, then the order is checked against what was actually found.

  3. STEP 3Clear Anvil · a few daysWritten scorecard

    Capture at the top of the list versus your current order, the drivers that mattered at your site, and where the model was wrong.

  4. STEP 4Both · your callSmall paid pilot, or stop

    If it earns its place: one live planning cycle on one unit, with your planners in the loop. Not a large software commitment.

Data boundaryNDA first. No client identifiers. Your data is not used to train anything and is deleted after the readout.
What you ownThe scorecard, the ranked list and the calibrated weights are yours, delivered as a written report.
What this is notNot a finished product, and not a replacement for RBI or API 583 practice. A narrow layer on top of the planning you already do.
About this page. Every circuit, attribute and finding above is generated sample data for a fictional unit. There are no client results here. The scoring is a starting point built from published guidance; the pilot exists to find out whether it beats your current order on your own history.